Manufacturer and distributor information is presented separately from the portal’s independent literature classification. Product-specific technical and regulatory information is sourced from manufacturer-controlled documentation. In case of discrepancy, the current IFU and product labelling prevail.
19corpus records referencing SENNEXthe device is named in the publication's full text
Manufacturer and Distributor
SENNEX® is manufactured by BIONMED TECHNOLOGIES GmbH, Saarbrücken, Germany, operating under an EN ISO 13485 quality-management system. DGMed Medikal distributes the system in Türkiye, Azerbaijan, Cyprus and Northern Cyprus.
For information about portal governance and commercial relationships, see About and Governance.
Intended Purpose and Indication
Relayed from the manufacturer’s instructions for use
The manufacturer’s instructions for use (V1.16.9 EN, 2024-12-04) state the intended purpose as follows: SENNEX®, with electroporation/electrochemotherapy (EPT/ECT), is used to treat cutaneous and subcutaneous tumours and metastases where palliative treatment is appropriate. The tumours are treated from the skin surface with minimally invasive needle electrodes and the procedure is combined with chemotherapy.
The same document states that the procedure may be carried out only in clinics, by academically trained physicians. Under indications it lists cutaneous and subcutaneous malignant tumours and metastases.
Clinical Publications Involving SENNEX
Corpus records whose source text names the device, grouped by publication type
Verified use in human clinical publications (5)
Publications in which the device was applied to patients, verified from the publication's own full text.
Eisele · J Oncol Res Ther · 2025 · Clinical Study · 7 patients · bleomycin · use evidenced in Methods
Landström et al · Melanoma Manag · 2022 · Case Report · 1 patients · cisplatin · use evidenced in Methods
Landström et al · Anticancer Res · 2021 · Case Report · 4 patients · bleomycin · use evidenced in Methods
Heppt et al · Cancer Immunol Immunother · 2016 · Retrospective Clinical Study · 33 patients · bleomycin · use evidenced in Methods
Kreuter et al · J Dtsch Dermatol Ges · 2015 · Retrospective Clinical Study · 56 patients · bleomycin · use evidenced in Methods
Verified preclinical use (5)
Publications in which the device was used in an animal, cell or model study, verified from the publication's own full text.
Spiliotis et al · Cancers (Basel) · 2025 · Animal Study · 24 animals · bleomycin · use evidenced in Methods
Spiliotis et al · Sci Rep · 2024 · Animal Study · 24 animals · bleomycin · use evidenced in Methods
Spiliotis et al · – · 2024 · Animal Study · 24 animals · bleomycin · use evidenced in Methods
Universitat des Saarlandes · – · 2024 · Animal Study · 24 animals · bleomycin · use evidenced in Methods
Spiliotis et al · Cancers (Basel) · 2023 · Animal Study · 32 animals · bleomycin · use evidenced in Methods
Other mentions of the device (9)
Reviews, consensus documents and device-landscape records; mentions reported in the studies a review covers; names appearing in a manufacturer or device discussion; and records whose role could not be settled. These do not show that the device was used in those studies.
Miklavcic et al · Radiol Oncol · 2026 · Review · named in the text
Tan et al · Cancers (Basel) · 2025 · Systematic Review / Meta-Analysis · 21 patients · named in the text
Gabay et al · Ann Biomed Eng · 2023 · In Silico / Modelling · 10 patients · bleomycin · named in the text
Chlebopaseviene ve Satkauskas · Health Sciences · 2021 · 1 patients · bleomycin · named in the text
Landström et al · Anticancer Res · 2021 · Case Report · 2 patients · bleomycin · named in the text
Pirc et al · Journal of Medical Devices · 2020 · Review · bleomycin · named in the text
Cvetkoska et al · IEEE Instrum. Meas. Mag. · 2020 · Review · bleomycin · named in the text
Tunikowska J, Kulbacka J, Michel O, Kiełbowicz Z · Weterynaria w Praktyce · 2018 · Review · bleomycin · named in the text
Landström FJ · – · 2015 · Review · 26 patients · bleomycin · named in the text
General ECT literature is classified independently throughout the portal. Inclusion of literature on this page indicates that SENNEX is explicitly identified in the source; it does not transfer aggregate study outcomes to the device unless device-specific results are reported separately. Each record keeps the portal's normal literature classification in its own drawer.
Publication titles are reproduced as published and do not represent claims made by DGMed or the manufacturer.
System and Electrode Configuration
Feature
As stated by the manufacturer
Electrode handles
LINEAR handle with 4 needle electrodes (Art. 70104-Q/L); PENTAGON handle with 6 needle electrodes (Art. 70106-H)
Needle electrodes
Supplied sterile, single use. The handle is not supplied sterile and is disinfected before each application.
Pulse count and amplitude
8 pulses per application, up to 1,000 V
Pulse duration and repetition
100 µs pulse duration, 10 pulses per second, 100 ms interpulse pause
Control channel
Passive galvanic element, up to 1 V DC. The instructions state that the measurement shows a tendency only and does not report a physical quantity with a defined measurement accuracy.
Electrical classification
Protection class I, type BF applied part; 100–240 V AC, 50/60 Hz, approximately 90 W
The values are taken from the manufacturer’s instructions for use and technical data sheet. Physical dimensions are stated differently in the two documents and are therefore not published here. A feature listed here does not thereby form part of an approved intended purpose.
Functional Principle
1
Chemotherapeutic agent
Bleomycin, or cisplatin as another frequently used chemotherapeutic agent, is injected around the tumour.
2
Electrode placement
The invasive electrodes are positioned on the affected part of the skin. The instructions state that it is vital in this process for the electric field to enclose the tumour completely.
3
High voltage pulses
The electrodes are charged with high voltage for several split seconds: 8 impulses of a maximum duration of 100 µs and 1,000 V amplitude are directed into the tumour.
4
Transient pores
According to the instructions, small pores emerge in the outer membranes of the cells in reaction to extremely short pulses of high voltage. The pores disappear after a short time; in the meantime it is possible for various substances to access the interior of the cells.
Relayed from section 4 of the instructions for use. The general, device-independent mechanism of electroporation is set out on the portal’s own Mechanisms page; the account here reflects a single manufacturer’s document and is not a statement of effectiveness.
Contraindications
The instructions carry a list of contraindications. In the document’s own words the list is not exhaustive; the attending physician decides on contraindications and treatment criteria.
Allergy to bleomycin
Cumulative bleomycin dose from earlier applications
Peripheral neuropathy above stage 2
Abnormal haemostasis
Chronic renal dysfunction
Clinically manifest arrhythmia
Patients with pacemakers or electronic implants
Epilepsy
Pregnancy and lactation
Acute infections
Assessment Before the Procedure
Assessment
As stated in the instructions
Pacemaker and implants
The presence of a pacemaker precludes treatment on the anterior chest wall.
Bleomycin sensitivity
Sensitivity to bleomycin or a history of pulmonary fibrosis precludes the administration of intravenous bleomycin.
Anticoagulant use
If the patient takes anticoagulants, the INR and prothrombin time are checked.
Anaesthetic allergy
Allergy against local anaesthesia, for example lidocaine, is asked about.
ECG
In cases of manifest or paroxysmal cardiac arrhythmias or previous cardiac events, an ECG before treatment is highly recommended.
Haematology
An INR above 1.5 precludes invasive electrode application. If the thrombocyte concentration is below 70,000/mm³, the decision to treat is made on the basis of the haematological opinion regarding the risk of bleeding versus the benefit of the therapy.
Biochemistry
If bleomycin is used intravenously, creatinine should be below 150 µmol/l to ensure adequate renal clearance.
Measurement of nodules
Nodules are measured and their local spreading recorded; photographic documentation is recommended before, during and after treatment.
Relayed from section 8.2 of the instructions for use. The table is not a patient selection criteria list and is not sufficient for clinical decision-making; the binding text is the manufacturer’s current instructions for use.
Procedure and Follow-up
The patient rests in a comfortable position on the electrically insulated couch.
The part of the skin to be treated is disinfected. Sterile covering is not necessary.
The anaesthetic is injected into the tissue surrounding the tumour.
Bleomycin is injected close to the tumour; multiple injections are allowed for larger tumours. Exposure times are provided by the injection timer according to the type of injection selected in the system, systemic or local.
The invasive needle electrodes are positioned so that the tumour lies between them. The operator determines the depth of penetration, 10 to 15 mm. Where larger blood vessels lie in the vicinity of the tumour, the application of the electrodes is monitored via ultrasound.
The gauze pad is taken in one hand and the electrodes in the other. The gauze pad allows the skin around the lesion to be lifted from the underlying muscles, thus avoiding additional injuries and unnecessary pain.
After the exposure period of the chemotherapy, 8 minutes for systemic and 30 seconds for local, the electric impulses are given; the injection timer and the active timer are observed.
Under local anaesthesia, the patient is informed when the first pulse is delivered.
Several impulses might be required in order to cover the tumour in its entirety. The instructions state that the applied electric field drops rapidly and drifts into the surrounding tissue, so exact positioning of the electrodes is crucial.
Repetition and follow-up
The instructions state that treatment can be repeated, and that on repetition the needles, handle and connection cable must be disinfected. If the bleomycin dose of 60,000 IU/m² is exceeded, a pulmonary function test is performed in order to detect a possible looming pulmonary fibrosis.
For follow-up the instructions ask the patient to return to the surgery within four weeks of treatment at the latest, and state that this period is sufficient for evaluating the effects of the treatment and deciding on further strategies. Convalescence is given as 4 to 8 weeks with small tumours and 10 weeks for lesions larger than 1.25 cm².
Relayed from sections 8.3.4 and 8.3.4.1 of the instructions for use. This summary does not replace an operating instruction; the procedure is carried out only in clinics, by physicians trained on the system, and the binding text is the manufacturer’s current instructions for use.
Regulatory Status
Field
As stated by the manufacturer
Device class (MDD)
IIb (Annex IX, 93/42/EEC; conformity assessment under Annex II)
Manufacturer
BIONMED TECHNOLOGIES GmbH
Basic UDI-DI
42624218470100KG
Notified body
Medical Device Certification GmbH (mdc), 0483
MDR transition status
Under the transitional provisions; the basis is the notified body's confirmation letter D1235100021, valid until 31 December 2028. A confirmation letter is not an MDR certificate.
The values are taken from the manufacturer's declaration of conformity (2024-05-15). The pictogram section of the instructions for use refers to Regulation (EU) 2017/745; the documentation reviewed shows the device as Class IIb under the MDD and within the notified body's transitional framework. The portal does not state that MDR certification has been completed. Approval and licensing status in your country is not assessed here; consult the record of your competent authority. The citations are on the Clearance and Assessment Documents page.
Publications That Name the Device
Corpus records whose full text names the device
Human studies (6)
Year
Publication
Study type
Model
2025
Eisele · J Oncol Res Ther
Clinical Study
Human
2022
Landström et al · Melanoma Manag
Case Report
Human
2021
Landström et al · Anticancer Res
Case Report
Human
2021
Landström et al · Anticancer Res
Case Report
Human
2016
Heppt et al · Cancer Immunol Immunother
Retrospective Clinical Study
Human
2015
Kreuter et al · J Dtsch Dermatol Ges
Retrospective Clinical Study
Human
Preclinical and animal studies (5)
Year
Publication
Study type
Model
2025
Spiliotis et al · Cancers (Basel)
Animal Study
Animal (In Vivo)
2024
Spiliotis et al · Sci Rep
Animal Study
Animal (In Vivo)
2024
Spiliotis et al · –
Animal Study
Animal (In Vivo)
2024
Universitat des Saarlandes · –
Animal Study
Animal (In Vivo)
2023
Spiliotis et al · Cancers (Basel)
Animal Study
Animal (In Vivo)
Reviews, guidelines and other (8)
Year
Publication
Study type
Model
2026
Miklavcic et al · Radiol Oncol
Review
Literature Analysis
2025
Tan et al · Cancers (Basel)
Systematic Review / Meta-Analysis
Literature Analysis
2023
Gabay et al · Ann Biomed Eng
In Silico / Modelling
Computational Model
2021
Chlebopaseviene ve Satkauskas · Health Sciences
–
–
2020
Pirc et al · Journal of Medical Devices
Review
Literature Analysis
2020
Cvetkoska et al · IEEE Instrum. Meas. Mag.
Review
Literature Analysis
2018
Tunikowska J, Kulbacka J, Michel O, Kiełbowicz Z · Weterynaria w Praktyce
Review
belirsiz
2015
Landström FJ · –
Review
Literature Analysis
The list is not maintained by hand: the full text of the 2,821 records in the portal’s corpus is searched and the records naming the device are collected here; at present 19 records meet that condition. General electrochemotherapy literature is not presented as evidence for this device: only publications naming the device are listed. Where a study used more than one system, its aggregate outcomes are not attributed to a single system; in a multicentre cohort some patients may have been treated with another system. The content of the publications, response rates and risk of bias are not assessed by the portal.
Clinical and Technical Data Reported in the Publications
Fields as reported in each publication's full text
The fields below are relayed as reported in the full text of the publications; no value is published unless it can be matched verbatim to its source. There is no human curation on this page. In 10 records there is Methods-section evidence that the device was used in that study; in the remaining records the device is named but there is no evidence of use. The portal does not assess these numbers, it relays them; the publication itself is the binding source.
Miklavcic et al · Radiol Oncol · 2026
Role of SENNEX in this publication: in a manufacturer or device discussion
Study designnarrative review
Electrode typeendoluminal electrode
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Eisele · J Oncol Res Ther · 2025
Role of SENNEX in this publication: used in this study · more than one system was used: SENNEX, four prong applicator
Study designprospective cohort
Subject studiedhuman
Patients7
Indicationbasal cell carcinoma
Lesion depthsuperficial cutaneous
Agent deliveredbleomycin
Routeintratumoural
Dose1000 I.U. Bleomycin per cm3 tumor volume
Field strength1000 V/cm
Pulses8
Pulse duration80 µs
Electrode typelinear needle array
Anaesthesialocal anaesthesia
Response criteriaRECIST 1.1
Grading systemauthor defined
EndpointValueDenominatorTimepointPopulation
complete response60 %5 patientswithin first 1-3 monthscurative
partial response40 %5 patientswithin first 1-3 monthscurative
complete response0 %2 patientswithin first 3 monthspalliative
partial response0 %2 patientswithin first 3 monthspalliative
Source (methods):The generator in use was the CE-certified SENNEX® system (Bionmed Technologies GmbH, 66123 Saarbrücken, Germany)
Source (methods):1000 I.U. Bleomycin ... per cm3 tumor volume was injected intralesionally
Source (methods):capable of delivering 8 successive pulses each with 80 µs duration. The reliable field strength is 1000 V/cm
Source (results):Complete (CR) or partial response (PR) was 0 % in p and 60 % (CR) or 40 % (PR) in c, respectively
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Spiliotis et al · Cancers (Basel) · 2025
Role of SENNEX in this publication: used in this study
Study designpreclinical in vivo
Subject studiedanimal
Indicationcolorectal hepatic metastases
Lesion depthdeep-seated visceral
Agent deliveredbleomycin
Routeintravenous
Dose4 U/kg body weight
Voltage1000 V
Field strength1250 V/cm
Pulses8
Pulse duration100 µs
Electrode typesingle needle pair
Anaesthesiageneral anaesthesia
EndpointValueDenominatorTimepointPopulation
tumour volume changeday 8 (pretreatment)animal
tumour volume changeanimal
Source:ECT was performed using the Sennex® Tumor System (BIONMED® Technologies GmbH, Saarbrücken, Germany).
Source (methods):BLM (BLEO-cell® 15 mg, STADAPHARM GmbH, Bad Vilbel, Germany) was administered through i.v. at a concentration of 4 U/kg body weight
Source (methods):Eight electric pulses, each with a duration of 100 µs, were delivered between the two electrodes three minutes after chemotherapy administration. ... the Sennex® Tumor System delivered a voltage of…
Source (results):BLM group exhibited the highest proportion of necrotic tissue, accounting for 82.6 ± 0.1% of the treated area
Source (methods):Twenty-four WAG/Rij rats (males: n = 12, females: n = 12)
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Tan et al · Cancers (Basel) · 2025
Role of SENNEX in this publication: reported in the included studies
Patients21
Response criteriaRECIST
Grading systemCTCAE
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Spiliotis et al · Sci Rep · 2024
Role of SENNEX in this publication: used in this study
Study designpreclinical in vivo
Subject studiedanimal
Indicationcolorectal hepatic metastases
Lesion depthdeep-seated visceral
Agent deliveredbleomycin
Routeintravenous
Dose4 U/kg body weight
Voltage1000 V
Field strength1250 V/cm
Pulses8
Pulse duration100 µs
Electrode typelinear needle array
Anaesthesiageneral anaesthesia
Source (methods):ECT was performed with the Sennex® Tumor System (BIONMED® Technologies GmbH, Saarbrücken, Germany)
Source (methods):BLM (BLEO-cell® 15 mg, STADAPHARM GmbH) was administered as an i.v. bolus injection at a concentration of 4 U/kg body weight
Source (methods):Eight electric pulses of 100 μs duration were applied between the two electrodes 3 min after the BLM injection
Source (results):The i.v. and i.v. + i.t. groups exhibited a 44.0% and 46.6% reduction in oxygen saturation of the tumor tissue when compared to pretreatment values
Source (methods):Twenty-four WAG/Rij rats of both gender (males: n = 12, females: n = 12)
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Spiliotis et al · – · 2024
Role of SENNEX in this publication: used in this study
Study designrandomized controlled trial
Subject studiedanimal
Lesions24
Indicationcolorectal hepatic metastases
Lesion depthdeep-seated visceral
Agent deliveredbleomycin
Routeintravenous
Dose4 U/kg body weight
Voltage1000 V
Field strength1250 V/cm
Pulses8
Pulse duration100 µs
Electrode typesingle needle pair
Anaesthesiageneral anaesthesia
Response criteriahistological
Grading systemauthor defined
EndpointValueDenominatorTimepointPopulation
tumour volume change39.7 cm³8 animalsday 8i.v group
tumour volume change39.5 cm³8 animalsday 8i.t. group
tumour volume change46 cm³8 animalsday 8i.v. + i.t. group
tumour volume change8 animalsday 13i.v. + i.t. group
tumour volume change8 animalsday 13i.v. group
tumour volume change8 animalsday 13i.t. group
tumour volume changeday 13all i.t. group
Source (not found):ECT was performed with the Sennex® Tumor System (BIONMED® Technologies GmbH, Saarbrücken, Germany)
Source (not found):BLM (BLEO-cell® 15 mg, STADAPHARM GmbH) was administered as an i.v. bolus injection at a concentration of 4 U/kg body weight
Source (not found):Eight electric pulses of 100 µs duration were applied between the two electrodes 3 min after the BLM injection
Source (not found):Twenty-four WAG/Rij rats of both gender (males: n = 12, females: n = 12)
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Source (methods):erhält BLM (BLEO-cell® 15 mg, STADAPHARM GmbH) in einer Dosis von 4 Einheiten pro kgKG (U/kgKG)
Source (methods):acht elektrische Impulse mit einer Dauer von 100 μs zwischen den beiden Elektroden erzeugt (SERSA et al., 2002). Die Spannung zwischen dem Elektrodenpaar ist auf 1000 V eingestellt, was einer…
Source (results):Der prozentuale Anteil des nekrotischen Gewebes in der BLM-Gruppe betrug 82,6 ± 0,1%
Source (methods):Die Tiere werden in drei Gruppen (n1=8, n2=8, n3=8) randomisiert und verteilt.
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Gabay et al · Ann Biomed Eng · 2023
Role of SENNEX in this publication: reported in the included studies
Study designother
Subject studiedhuman
Patients10
Lesions10
Indicationbasal cell carcinoma
Lesion depthsuperficial cutaneous
Agent deliveredbleomycin
Routeintravenous
Voltage750 V
Pulses40
Pulse duration40 µs
Electrode typecustom or experimental
Source (not found):40 pulses, 40 μs, and 4 Hz pulses were delivered at 750, 500, or 250 V. In the second step, 40 pulses, 10 ms, and 4 Hz pulses were delivered at 50 V.
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Spiliotis et al · Cancers (Basel) · 2023
Role of SENNEX in this publication: used in this study
Study designpreclinical in vivo
Subject studiedanimal
Lesions32
Indicationcolorectal hepatic metastases
Lesion depthdeep-seated visceral
Agent deliveredbleomycin
Routeintravenous
Dose4 U/kg body weight
Voltage1000 V
Field strength1250 V/cm
Pulses8
Pulse duration100 µs
Electrode typelinear needle array
Anaesthesiageneral anaesthesia
Source (methods):The electrodes were inserted in a plastic holder and connected to the electric pulse generator (Sennex® Tumor System, BIONMED® Technologies GmbH, Saarbrücken, Germany)
Source (methods):BLM (BLEO-cell® 15 mg, Stadapharm GmbH, Bad Vilbel, Germany) was administrated as an intravenous bolus injection at a concentration of 4 U/kg body weight
Source (methods):Eight electric pulses of 100 µs duration were applied between the two electrodes 3 min after the BLM injection. According to the European guidelines for the utilization of ECT, the Sennex® Tumor…
Source (results):The histological analysis revealed a higher rate of tumor necrosis in the ECT group, which was estimated at 87.2 ± 3.1%
Source (methods):Thirty-two WAG/Rij rats of both gender (males n = 16, females n = 16) with a body weight of 265.0 ± 14.5 g and an age of 46.0 ± 1.9 weeks were used for the experiments
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Landström et al · Melanoma Manag · 2022
Role of SENNEX in this publication: used in this study
Study designcase report
Subject studiedhuman
Patients1
Lesions1
Indicationcutaneous malignant melanoma
Lesion depthsubcutaneous
Agent deliveredcisplatin
Routeintratumoural
Dose18 ml cisplatin (Sandoz, Copenhagen, Denmark) with a concentration of 1 mg/ml
Field strength1100 V/cm
Pulses8
Pulse duration100 µs
Electrode typehexagonal needle array
Anaesthesiageneral anaesthesia
Response criteriaclinical examination
Grading systemauthor defined
EndpointValueDenominatorTimepointPopulation
tumour volume change2 weekspatient
tumour volume change6 weekspatient
tumour volume change7 monthspatient
Source:Electroporation was then performed using the Sennex electroporation system (Bionmed, Saarsbrucken, Germany) with 16 complete applications using the six-needle applicator.
Source (methods):Local injection of 18 ml cisplatin (Sandoz, Copenhagen, Denmark) with a concentration of 1 mg/ml in accordance with the ESOPE protocol was administered
Source (methods):The Sennex system delivers eight 0.1 ms square-wave pulses per application with electric field strength 1100 V/cm
Source (abstract):a 68-year-old woman with a large therapy resistant inguinal lymph node melanoma metastasis
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Chlebopaseviene ve Satkauskas · Health Sciences · 2021
Role of SENNEX in this publication: reported in the included studies
Study designnarrative review
Patients1
Agent deliveredbleomycin
Source:Aprašomas 80 metų vyro ligos atvejis
Landström et al · Anticancer Res · 2021
Role of SENNEX in this publication: in a manufacturer or device discussion · more than one system was used: MedPulser, Cliniporator
Study designcase series
Subject studiedhuman
Patients2
Indicationbasal cell carcinoma and cutaneous squamous cell carcinoma
Source (not found):After bleomycin administration electroporation was performed with either the Cliniporator (IGEA, Carpi, Italy) or the Sennex (Bionmed, Saarbrucken, Germany) electroporation systems.
Source (not found):bleomycin was administered intratumorally including a 1 cm margin of macroscopically normal tissue. The dose was 1000 IE per cm3 of tumor volume
Source (not found):There was one recurrence recorded in the 56-month follow-up period.
Pirc et al · Journal of Medical Devices · 2020
Role of SENNEX in this publication: in a manufacturer or device discussion
Study designnarrative review
Agent deliveredbleomycin
Routeintravenous
Anaesthesiageneral anaesthesia
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Cvetkoska et al · IEEE Instrum. Meas. Mag. · 2020
Role of SENNEX in this publication: in a manufacturer or device discussion
Study designnarrative review
Indicationcancer
Agent deliveredbleomycin
Voltage1000 V
Pulses8
Pulse duration100 µs
Electrode typeparallel plate
Anaesthesialocal anaesthesia
Source (not found):For each pulse delivering, 8 square-wave pulses of 100 μs with pulse amplitude of about 1000 V (1000 V up to 1300 V) across an 8 mm distance between plate electrodes should be delivered at repetition…
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Tunikowska J, Kulbacka J, Michel O, Kiełbowicz Z · Weterynaria w Praktyce · 2018
Role of SENNEX in this publication: background mention
Study designnarrative review
Agent deliveredbleomycin
Routeboth intravenous and intratumoural
DoseBleomycynę podaje się w stężeniu 3 mg/ml w dawce wynoszącej 30 mg/m2 powierzchni ciała
Field strength1300 V/cm
Pulses8
Pulse duration100 µs
Electrode typecustom or experimental
Anaesthesiageneral anaesthesia
Source (not found):Bleomycynę podaje się w stężeniu 3 mg/ml w dawce wynoszącej 30 mg/m2 powierzchni ciała
Source (not found):Większość urządzeń służących do ECT składa się z elektroporatora, generującego serię 8 impulsów elektrycznych trwających 100 μs o częstotliwości 1 Hz oraz natężeniu 1300 V/cm lub 1000 V/cm
Heppt et al · Cancer Immunol Immunother · 2016
Role of SENNEX in this publication: used in this study · more than one system was used: Cliniporator, SENNEX
Study designretrospective cohort
Subject studiedhuman
Patients33
Median follow-up9 months
Indicationadvanced melanoma
Lesion depthsuperficial cutaneous
Agent deliveredbleomycin
Routeintravenous
Dose15,000 IU/m2 body surface area if given intravenously and at 250–500 IU/cm3 of tumor tissue if applied intralesionally
Voltage1000 V
Electrode typelinear needle array
Anaesthesiageneral anaesthesia
Response criteriaRECIST 1.1
Grading systemCTCAE
EndpointValueDenominatorTimepointPopulation
local control75.8 %33 patients3 monthsentire cohort
local control66.7 %33 patients3 monthsentire cohort
Source (methods):High-voltage pulses (730–1000 V) were applied to cutaneous target lesions with a Cliniporator™ (IGEA, Carpi, Italy) or Sennex® (BIONMED Technologies, Saarbrücken, Germany) pulse generator
Source (methods):Bleomycin was used for ECT in all cases at doses of 15,000 IU/m2 body surface area if given intravenously and at 250–500 IU/cm3 of tumor tissue if applied intralesionally.
Source (methods):High-voltage pulses (730–1000 V) were applied to cutaneous target lesions with a Cliniporator™ (IGEA, Carpi, Italy) or Sennex® (BIONMED Technologies, Saarbrücken, Germany) pulse generator 8–28 min…
Source (abstract):The local overall response rate (ORR) was 66.7 %. The systemic ORR was 19.2 and 40.0 % in the ipilimumab and PD-1 cohort, respectively.
Source (abstract):A total of 33 patients from 13 centers were identified with a median follow-up time of 9 months.
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Landström FJ · – · 2015
This record is a review; SENNEX appears in the studies it covers
Patients26
Agent deliveredbleomycin
Routeintratumoural
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.
Kreuter et al · J Dtsch Dermatol Ges · 2015
Role of SENNEX in this publication: used in this study · more than one system was used: Cliniporator, SENNEX
Study designretrospective cohort
Subject studiedhuman
Patients56
Agent deliveredbleomycin
Routeintravenous
Dose15 mg/m^2 body surface area
Electrode typeparallel plate
Response criteriaRECIST
Source:Two devices were used for ECT: Cliniporator (IGEA GmbH, Frankfurt am Main, Germany) in 50 patients and Sennex (BIONMED Technologies GmbH, Saarbrücken, Germany) in six patients.
Source:56 patients treated with electrochemotherapy
This record does not cover the whole text of the publication, so an empty field does not necessarily mean the publication failed to report it.